SAG mill - design improvement for prevention form water leakage
| dc.contributor.author | Baljinnyam, Naranmisheel | |
| dc.contributor.author | Norovrinchen, Odbileg Prof. Dr. | |
| dc.contributor.author | Tumur, Gurragchaa | |
| dc.date.accessioned | 2026-11-24T03:59:08Z | |
| dc.date.issued | 2026-05-01 | |
| dc.description | Bachelor's thesis submitted to the Faculty of Mechanical and Electrical Engineering, German-Mongolian Institute for Resources and Technology (GMIT). Supervisor 1: Prof. Dr. Odbileg Norovrinchen. Supervisor 2: Mr. Gurragchaa Tumur. Ulaanbaatar/Nalaikh, 2026. | |
| dc.description.abstract | Semi-autogenous grinding (SAG) mills at the Oyu Tolgoi copper-gold concentrator in Mongolia are the primary comminution assets of the operation, each rated at 20,000 kW and processing a combined average of approximately 4,981 dry metric tonnes per hour — exceeding the FLSmidth design throughput of 4,428 MTPH. Operating with approximately 1,700 m³/h of process water per mill, these mills are continuously exposed to water ingress risk at two critical interfaces: the feed-end trunnion bearing cavity and the gearless motor stator housing. This thesis applies four integrated methods to investigate water ingress and propose engineering improvements: DCS operational data analysis (January–April 2026); Failure Mode and Effect Analysis; 3D CAD modelling in Autodesk Inventor; and SPH-DEM simulation in ANSYS Rocky Student Version. The simulation was conducted on CPU only — the student licence does not include GPU acceleration — using ore particles and an SPH water phase without grinding balls, which represents a lower-bound pressure condition. Thermal analysis of lube oil and motor windings is explicitly excluded from scope. The thesis focuses entirely on water ingress pathways, their fluid-mechanical characterisation, and structural design of protective measures. Four water ingress pathways were identified. FMEA ranked the stator gap lower section (P1, RPN 432) and the trunnion seal (P2, RPN 392) as the two highest-priority continuously active pathways. SPH-DEM simulation produced a time-averaged water impact pressure of approximately 4,800 Pa at the feed-end trunnion bore lower half and approximately 1,980 Pa at the lower stator gap zone, confirming that dynamic charge ejection from the ore-only simulation drives significant water loading at both interfaces even without the additional mass of the grinding ball charge. Three engineering proposals are developed. Proposal 1 (bolt-hole plug sealing procedure, AISI 316L stainless steel threaded plugs with O-ring face seals) eliminates the highest-severity failure mode FM-03 (RPN 280, acute stator fault during liner change) and can be implemented at the next planned liner change for approximately USD 2,400. Proposal 2 (semi-circular arc bearing protection cover hood, ASTM A36, 180°, 850 mm axial span, bolted) physically encloses the feed-end bearing housing, eliminating overhead water access to pathways P2 and P4 entirely and independently of seal condition. Structural calculations confirm that an 8 mm plate with 3 mm corrosion allowance, four 100×10 mm transverse stiffeners at 280 mm spacing, and 16 M20 Grade 8.8 bolts satisfies all stress, deflection, weld, drainage, and clearance requirements — maintaining 34.993 mm residual clearance from the rotating trunnion OD under worst-case dynamic conditions. Proposal 3 (stator gap cover plate concept) is identified as a geometrically constrained idea: the 15 mm rotor-stator air gap is insufficient to accommodate a cover plate of practical fabrication thickness with adequate running clearance, dynamic envelope margin, and gravity drainage in the same space. The concept is retained as a high-value future engineering investigation requiring purpose-machined labyrinth inserts or an active drainage system. | |
| dc.identifier.other | B2200423 | |
| dc.identifier.uri | https://gmitlibrary.net/handle/123456789/262 | |
| dc.language.iso | en | |
| dc.publisher | German-Mongolian Institute for Resources and Technology | |
| dc.subject | SAG mill | |
| dc.subject | Water ingress | |
| dc.subject | Autodesk Inventor | |
| dc.subject | ANSYS Rocky | |
| dc.subject | SPH-DEM | |
| dc.subject | FMEA | |
| dc.subject | Trunnion seal | |
| dc.subject | Bearing protection cover | |
| dc.subject | Stator gap | |
| dc.subject | ASTM A36 | |
| dc.subject | Oyu Tolgoi | |
| dc.subject | Gearless motor drive | |
| dc.title | SAG mill - design improvement for prevention form water leakage | |
| dc.type | Thesis |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- Naranmisheel_Baljinnyam_Bachelor_Thesis.pdf
- Size:
- 2.39 MB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed to upon submission
- Description: