    Modeling and Simulation of Relay Protection for Industrial Power Network Distributed Generation
    (German-Mongolian Institute for Resources and Technology (GMIT), 2026) Batjargal, Javkhlan; Supervisor 1: Mr. Nikita Abramovich; Supervisor 2: Mr. Taivanbaatar Lkhagvasuren
    This thesis presents the design and simulation of a relay protection system for the industrial power network of the Khan Altai Resource gold mining facility located in Govi-Altai Province, western Mongolia. The mine operates on a hybrid power supply consisting of a 35 kV overhead transmission line from the Altai-Uliastai external grid as the primary source, backed by three diesel generator sets of 1,250 kVA each. With peak demand projected to grow from 4,873 kW to 8,421 kW between 2026 and 2029, and a planned integration of wind generation, the existing protection infrastructure requires systematic review and upgrading. Short-circuit currents at four critical fault points in the network were calculated in accordance with IEC 60909:2016 using the method of symmetrical components, covering three phases, phase-to-phase, and single-phase-to-earth fault scenarios under both maximum and minimum source contribution conditions. Based on these results, current and voltage instrument transformers and switching equipment were selected. Main and backup protection schemes were developed for the 35 kV overhead transmission line and 10 kV distribution feeders, including overcurrent, directional, earth fault, automatic reclosing, and automatic transfer switching functions. Setting calculations were performed per IEC 60255- 151, and microprocessor-based relay devices were selected and configured. The complete protection scheme was modelled and validated through simulation in DIgSILENT PowerFactory, confirming that selectivity, sensitivity, and operating speed requirements are satisfied across all credible fault and operating conditions.